Emergency refuge forms an integral part of an underground mine’s wider Emergency Response Plan (ERP). Fires, explosions, rock-falls, flooding and the release of smoke and other forms of toxic gas are the types of incidents that occur all too frequently, despite the high levels of planning and the safety precautions in place. In these types of emergencies, when evacuation is no-longer safe or practical, emergency refuge is designed to provide a safe and secure ‘go-to’ area for personnel to gather and await extraction.
 
  
Helping safeguard miners in over 40 countries, across six continents, the MineARC MineSAFE series is the world’s most trusted refuge chamber in metal (hard rock) and non-metal mines.

  • MineSAFE Standard Design

    MineARC MineSAFE Standard Design

    In consultation with the world’s leading mining companies and regional mining authorities, the MineARC MineSAFE has been continuously re-engineered and refined to create a safe-refuge solution that is fully integrated with today’s modern underground mining environment.
     
    Now in its fourth series, the MineSAFE Standard Design (SD) Refuge Chamber provides miners with optimum safety features, functionality and performance.
     
    Standard configurations are available based on occupancy – from 8 to 30 people – with each model engineered for maximum durability and manoeuvrability, both above and below ground. – More information

    Image
    Image

     

    MineSAFE SD Series

     

     


     

    Inside a MineSAFE Standard Design Refuge Chamber, a number of vital life-support systems combine to create a safe, ongoing environment for occupants. The chamber features a MineARC Series IV Controller; the most advanced safe-refuge technology anywhere in the world.

    Ultimately an SD refuge chamber’s dimensions and its rated occupancy can be custom-engineered to site specifications, without compromising on safety or performance.

    Special transport configurations include narrow builds specifically tailored for shaft mines, or modular builds, allowing a complete refuge chamber to be split into smaller sections before being transported and then reassembled underground.

     

    360º INTERNAL VIEW

    Click and drag to explore the refuge chamber.

     

     

    STANDARD FEATURES

    OPTIONAL FEATURES

    ENQUIRE BROCHURE

     

     

    CHAMBER EXTERIOR - FRONT

    Strobe Lighting

    Extra low voltage green and red LED lighting to allow for easy identification of the refuge chamber in an emergency.

    Porthole Window

    12mm porthole viewing window, compliant with Australian Standard 2208. Blast shield protection available upon request.

    Fire Extinguisher

    Fire extinguisher for external use only. Optional for non-Australian orders (supplied separately as Dangerous Goods). Fire blanket with BSI certification (AS/NZ S 3504) located inside chamber.

    Siren

    112 dBA motion activated siren to allow for easy location of the refuge chamber in an emergency.

    Reflective Signage

    Safety and operational signage in reflective stickering for high visibility underground. Translation into a second language available.

    Paint

    High durability white paint for underground visibility. Sand blasted to 2.5 grit, and in compliance with AS/NZS 2312:2002.

    Sealing Door

    Outward opening door, featuring double locking rotating handles. The vacuum tested seal maintains a positive internal pressure.

    Skid Base

    The skid base provides ease of mavoeuvrability, featuring 250 x 100mm forklift slots, front and rear mounted tow points and front mounted 25mm steel plate push blocks.

    Lifting Lugs

    On roof of chamber.

     

     

    CHAMBER INTERIOR

    Air Conditioning

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Series IV Controller Interface

    The digital controller interface is the operational hub of the refuge chamber. From here, all power, lighting & scrubbing systems can be managed with the push of a button. Click for more information.

    Seating

    MineARC seating is ergonomically designed to provide suitable comfort during entrapment. Made from durable, hard wearing fabric, the seating provides 500mm of space per person.

    Series IV Scrubber System

    The MineSAFE Standard Design uses active chemicals and MineARC's patented Series IV scrubbing system to ‘scrub’ the build up of harmful CO2 and CO from the chamber.

    Oxygen Supply #1: Mine Air

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers.

    Emergency Escape Hatch

    Inward opening with neoprene memory seal. Accessible internally and externally.

    MARCISORB Chemical Cartridges

    MineARC’s MARCISORB CO2 and MARCISORB CO cartridges provide superior scrubbing capacity, are easy to load, safe to handle, and can store for long periods.

    Oxygen Supply #2: Medical Grade Oxygen Cylinders

    Minimum capacity based on G-size cylinder (8,580L). Medical grade oxygen cylinders to be provided by end user.

    Storage

    Ample storage room located under seating and within Series IV Scrubber cabinet.

    Oxygen Supply #3: Oxygen Candle

    The military approved Oxygen candle provides 2,600L of breathable air during 60 minutes of ignition. Candle is an optional feature for most countries, and must be shipped separately.

    Flooring

    Non slip, removable flooring is featured throughout the refuge chamber.

    Lighting

    8watt fluorescent interior lighting is featured within the chamber.

    Operating Procedures

    Operating procedures are located on the wall of the refuge chamber, as well as within hardcopy manuals. Operating procedures can be translated into a second language.

    Aura-FX Digital Gas Monitor

    • Real-time gas monitoring with live analysis and voice prompting
    • Monitor up to 11 gases at any one time

     

     

    CHAMBER EXTERIOR - REAR

    Communications Box

    Communications box for internal communications port via wall mounted 'J' box. External antenna is fitted to front of chamber.

    Battery UPS

    36 hour emergency backup power supply, with further options available for up to 96 hours (POA).

    CAMS

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    Air Conditioning Condenser

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

     

    ENQUIRE BROCHURE

     


    Image
  • MineSAFE Essential Design

    The MineSAFE Essential Design (ED) provides the most cost effective alternative to MineARC’s flagship Standard Design refuge chamber. The ED chamber offers all of the critical features required to sustain life during an emergency whilst maintaining the quality of a MineARC engineered
    refuge chamber.
     
    The Essential Design is designed specifically to accommodate tight mining confines such as shaft mines, while still providing ample internal space for a range of occupancies – from 8 to 26 people. The chamber’s narrow design makes it easy to manoeuvre and position around site. – More information

    Image
    Image

     

    minesafe-ed-series

     


     

    Inside a MineSAFE Essential Design Refuge Chamber, a number of vital life support systems combine to create a safe, ongoing environment for occupants. Systems include primary and secondary oxygen supplies, air conditioning systems, positive pressure systems, electrical systems, gas detection and CO/CO2 absorption systems (referred to as ‘scrubbing’ systems).

    Ultimately an ED refuge chamber’s dimensions and its rated occupancy can be custom-engineered to site specifications, without compromising on safety or performance.

     

    STANDARD FEATURES

    OPTIONAL FEATURES

    ENQUIRE BROCHURE

     

     

    CHAMBER EXTERIOR - FRONT

    Strobe Lighting

    Extra low voltage green and red LED lighting to allow for easy identification of the refuge chamber in an emergency.

    Siren

    112 dBA motion activated siren to allow for easy location of the refuge chamber in an emergency.

    Lifting Lugs

    On roof of chamber.

    Air Vent / Check Valve

    Paint

    High durability white paint for underground visibility. Sand blasted to 2.5 grit, and in compliance with AS/NZS 2312:2002.

    Reflective Signage

    Safety and operational signage in reflective stickering for high visibility underground. Translation into a second language available.

    Skid Base

    The skid base provides ease of mavoeuvrability, featuring 250 x 100mm forklift slots, front and rear mounted tow points and front mounted 25mm steel plate push blocks.

    Porthole Window

    12mm porthole viewing window, compliant with Australian Standard 2208. Blast shield protection available upon request.

    Sealing Door

    Outward opening door, featuring double locking rotating handles. The vacuum tested seal maintains a positive internal pressure.

     

     

    CHAMBER INTERIOR

    Interior Lighting

    8 watt flourescent

    Emergency Escape Hatch

    Inward opening with neoprene memory seal. Accessible internally and externally.

    Oxygen Supply #1: Mine Air

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers.

    ELV Scrubber System

    The MineSAFE Essential Design uses active chemicals and MineARC's extra-low-voltage scrubbing system to ‘scrub’ the build up of harmful CO2 and CO from the chamber.

    Aura-FX Digital Gas Monitor

    Scrubber Air Vent

    Flooring

    Non slip, removable flooring is featured throughout the refuge chamber.

    Storage

    Ample storage room located under seating.

    Seating

    MineARC seating is ergonomically designed to provide suitable comfort during entrapment. Made from durable, hard wearing fabric, the seating provides 500mm of space per person.

    Operating Procedures

    Operating procedures are located on the wall of the refuge chamber, as well as within hardcopy manuals. Operating procedures can be translated into a second language.

    Air Conditioning

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

     

     

    CHAMBER EXTERIOR - REAR

    CAMS

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers.

    Air Conditioning Condenser

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Dual Battery Backup (UPS) System

    36 hour emergency backup power supply, with further options available for up to 96 hours (POA).

     

    ENQUIRE BROCHURE

     


    Image
  • MineSAFE Narrow Design

    The MineSAFE Narrow Design (ND) features a slimmer shell, designed specifically to accommodate tight hard rock mining confines such as shaft mines, while still providing ample internal space for a range of occupancies – from 8 to 26 people.
     
    The chamber’s portable design makes it easy to manoeuvre and position around site. – More information

    Image
    Image

     

    MineSAFE ND Series

     

     


     

    Inside a MineSAFE Narrow Design Refuge Chamber, a number of vital life support systems combine to create a safe, ongoing environment for occupants. Systems include primary and secondary oxygen supplies, air conditioning systems, positive pressure systems, electrical systems, gas detection and CO/CO2 absorption systems (referred to as ‘scrubbing’ systems).

    Ultimately an ND refuge chamber’s dimensions and its rated occupancy can be custom-engineered to site specifications, without compromising on safety or performance.

     

    STANDARD FEATURES

    OPTIONAL FEATURES

    ENQUIRE BROCHURE

     

     

    CHAMBER EXTERIOR - FRONT

    Siren

    112 dBA motion activated siren to allow for easy location of the refuge chamber in an emergency.

    Lifting Lugs

    On roof of chamber.

    Strobe Lighting

    Extra low voltage green and red LED lighting to allow for easy identification of the refuge chamber in an emergency.

    Porthole Window

    12mm porthole viewing window, compliant with Australian Standard 2208. Blast shield protection available upon request.

    Sealing Door

    Outward opening door, featuring double locking rotating handles. The vacuum tested seal maintains a positive internal pressure.

    Skid Base

    The skid base provides ease of mavoeuvrability, featuring 250 x 100mm forklift slots, front and rear mounted tow points and front mounted 25mm steel plate push blocks.

    Reflective Signage

    Safety and operational signage in reflective stickering for high visibility underground. Translation into a second language available.

    Paint

    High durability white paint for underground visibility. Sand blasted to 2.5 grit, and in compliance with AS/NZS 2312:2002.

    Fire Extinguisher

    Fire extinguisher for external use only. Optional for non-Australian orders (supplied separately as Dangerous Goods). Fire blanket with BSI certification (AS/NZ S 3504) located inside chamber.

     

     

    CHAMBER INTERIOR

    Air Conditioning

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Operating Procedures

    Operating procedures are located on the wall of the refuge chamber, as well as within hardcopy manuals. Operating procedures can be translated into a second language.

    Not Pictured: MARCISORB Chemical Cartridges

    MineARC’s MARCISORB CO2 and MARCISORB CO cartridges provide superior scrubbing capacity, are easy to load, safe to handle, and can store for long periods.

    Flooring

    Non slip, removable flooring is featured throughout the refuge chamber.

    ELV Scrubber System

    The MineSAFE Narrow Design uses active chemicals and MineARC's extra-low-voltage scrubbing system to ‘scrub’ the build up of harmful CO2 and CO from the chamber.

    Seating

    MineARC seating is ergonomically designed to provide suitable comfort during entrapment. Made from durable, hard wearing fabric, the seating provides 500mm of space per person.

    Oxygen Supply #1: Mine Air

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers.

    ELV Controller Interface

    The digital controller interface is the operational hub of the refuge chamber. From here, all power, lighting & scrubbing systems can be managed with the push of a button.

    Aura-FX Digital Gas Monitor

    • Real-time gas monitoring with live analysis and voice prompting
    • Monitor up to 11 gases at any one time

     

     

    CHAMBER EXTERIOR - REAR

    CAMS

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    Air Conditioning Condenser

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Battery UPS

    36 hour emergency backup power supply, with further options available for up to 96 hours (POA).

    Communications Box

    Communications box for internal communications port via wall mounted 'J' box. External antenna is fitted to front of chamber.

     

    ENQUIRE BROCHURE

     


    Image
  • MineSAFE Compact Design

    The MineSAFE Compact Design (CD) is designed specifically for tight mining confines, such as single-entry development headings. This small, compact, ultra-portable refuge chamber is easy to manoeuvre and position around site.
     
    The Compact Design is designed for optimum autonomy. The chamber’s ‘extra-low-voltage’ control system means it can sit stand-alone for extended periods without requiring connection to mains (mine) power (around 6 weeks). – More information

    Image
    Image

     

    MineSAFE CD Series

     

     


     

    Inside a MineSAFE Compact Design Refuge Chamber, a number of vital life-support systems combine to create a safe, ongoing environment for occupants. Systems include primary and secondary oxygen supplies, air conditioning systems, positive pressure systems, electrical systems, gas detection and CO/CO2 absorption systems (referred to as ‘scrubbing’ systems).

    Ultimately a MineSAFE CD's dimensions and its rated occupancy can be custom-engineered to site specifications, without compromising on safety or performance. Standard configurations are based on 4, 6 and 8 person occupancies, with a range of optional features.

     

    STANDARD FEATURES

    ENQUIRE BROCHURE

     

     

    CHAMBER EXTERIOR - FRONT

    Lifting Lugs

    On roof of chamber.

    Siren

    112 dBA motion activated siren to allow for easy location of the refuge chamber in an emergency.

    Strobe Lighting

    Extra low voltage green and red LED lighting to allow for easy identification of the refuge chamber in an emergency.

    Porthole Window

    12mm porthole viewing window, compliant with Australian Standard 2208. Blast shield protection available upon request.

    Paint

    High durability white paint for underground visibility. Sand blasted to 2.5 grit, and in compliance with AS/NZS 2312:2002.

    Reflective Signage

    Safety and operational signage in reflective stickering for high visibility underground. Translation into a second language available.

    Sealing Door

    Outward opening door, featuring double locking rotating handles. The vacuum tested seal maintains a positive internal pressure.

    Forklift Slots

    250 x 100mm forklift slots provide ease of manoeuvrability within tight mining confines.

     

     

    CHAMBER INTERIOR

    Air Conditioning

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Operating Procedures

    Operating procedures are located on the wall of the refuge chamber, as well as within hardcopy manuals. Operating procedures can be translated into a second language.

    Not Pictured: MARCISORB Chemical Cartridges

    MineARC’s MARCISORB CO2 and MARCISORB CO cartridges provide superior scrubbing capacity, are easy to load, safe to handle, and can store for long periods.

    ELVP Controller Interface

    The digital controller interface is the operational hub of the refuge chamber. From here, all power, lighting & scrubbing systems can be managed with the push of a button.

    Flooring

    Non slip, removable flooring is featured throughout the refuge chamber.

    Seating

    MineARC seating is ergonomically designed to provide suitable comfort during entrapment. Made from durable, hard wearing fabric, the seating provides 500mm of space per person.

    ELVP Scrubber System

    The MineSAFE Compact Design uses active chemicals and MineARC's extra-low-voltage-portable scrubbing system to ‘scrub’ the build up of harmful CO2 and CO from the chamber.

    Oxygen Supply #1: Mine Air

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    Aura-FX Digital Gas Monitor

    • Real-time gas monitoring with live analysis and voice prompting
    • Monitor up to 11 gases at any one time

     

     

    CHAMBER EXTERIOR - REAR

    CAMS

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    Air Conditioning Condenser

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Battery UPS

    36 hour emergency backup power supply, with further options available hours (POA). A dual UPS enables the chamber to sit standalone from mains power for extended durations.

     

    ENQUIRE BROCHURE

     


    Image
  • MineSAFE Modular Design

    The MineSAFE Modular Design range is engineered specifically to accommodate tight underground confines and mines with restricted access, while still providing sufficient internal space to comply with international best practice guidelines. The range is designed to be easily manoeuverable around sharp corners and within tight mine shafts; it’s modular construction means each section can fit within a cage and then be fully assembled underground.
     
    Standard configurations area available based on occupancy – from 12 to 32 people. Each section of the refuge chamber features forklift slots and lifting lugs for easy transportation on-site.
    – More information

    Image
    Image

     

    MineSAFE Standard Design Modular Series

     


     

    Assembly of a Modular refuge chamber is a simple process that can take place on-site once all sections have been transported underground. Each section features a heavy duty flange arrangement, allowing the chamber to bolt together easily once a seal has been applied. MineARC's user-friendly electrical system features a plug-and- play connection between each modular section to make a fully functioning refuge chamber.

     

    STANDARD FEATURES

    • Aura-FX Fixed Gas Monitoring
    • Modular, Manoeuverable Design for Tight Mining Confines
    • 5mm Steel Plate Construction with Reflective Signage
    • Skid Base with Additional Forklift Slots and Lifting Lugs
    • Blast Rating: 5psi
    • Compressed Air Management System (CAMS)
    • Advanced Series IV Digital Control System with i.V.A.N
    • CO and CO2 Scrubbing (Pre-packaged Chemical Cartridges)
    • Breathable Air (O2) Supply
    • Air Conditioning and Dehumidifying
    • Battery Backup (UPS) - 36hrs Minimum
    • Internal/External Communications and Lighting
    • Viewing Portal and Rear Escape Hatch

    OPTIONAL FEATURES

    ENQUIRE BROCHURE

     

     

    CHAMBER EXTERIOR - FRONT

    Lifting Lugs

    On roof of chamber.

    Siren

    112 dBA motion activated siren to allow for easy location of the refuge chamber in an emergency.

    Strobe Lighting

    Extra low voltage green and red LED lighting to allow for easy identification of the refuge chamber in an emergency.

    Heavy Duty Flange Arrangement

    On all modular sections for simple connection.

    Reflective Signage

    Safety and operational signage in reflective stickering for high visibility underground. Translation into a second language available.

    Paint

    High durability white paint for underground visibility. Sand blasted to 2.5 grit, and in compliance with AS/NZS 2312:2002.

    Skid Base

    The skid base provides ease of mavoeuvrability, featuring 250 x 100mm forklift slots, front and rear mounted tow points and front mounted 25mm steel plate push blocks.

    Sealing Door

    Outward opening door, featuring double locking rotating handles. The vacuum tested seal maintains a positive internal pressure.

    Porthole Window

    12mm porthole viewing window, compliant with Australian Standard 2208. Blast shield protection available upon request.

     

     

    CHAMBER INTERIOR

    Lighting

    8watt fluorescent interior lighting is featured within the chamber.

    Air Conditioning

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    Operating Procedures

    Operating procedures are located on the wall of the refuge chamber, as well as within hardcopy manuals. Operating procedures can be translated into a second language.

    Oxygen Supply #1: Mine Air

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    MARCISORB Chemical Cartridges

    MineARC’s MARCISORB CO2 and MARCISORB CO cartridges provide superior scrubbing capacity, are easy to load, safe to handle, and can store for long periods.

    Flooring

    Non slip, removable flooring is featured throughout the refuge chamber.

    Storage

    Ample storage room located under seating and within Series IV Scrubber cabinet.

    Oxygen Supply #3: Oxygen Candle

    The military approved Oxygen candle provides 2,600L of breathable air during 60 minutes of ignition. Candle is an optional feature for most countries, and must be shipped separately.

    Oxygen Supply #2: Medical Grade Oxygen Cylinders

    Minimum capacity based on G Size cylinder (8,580L). Medical grade oxygen cylinders to be provided by end user.

    Seating

    MineARC seating is ergonomically designed to provide suitable comfort during entrapment. Made from durable, hard wearing fabric, the seating provides 500mm of space per person.

    Series IV Controller Interface

    The digital controller interface is the operational hub of the refuge chamber. From here, all power, lighting & scrubbing systems can be managed with the push of a button. Click for more information.

    Series IV Scrubber System

    The MineSAFE Standard Design uses active chemicals and MineARC's patented Series IV scrubbing system to ‘scrub’ the build up of harmful CO2 and CO from the chamber.

    Heavy Duty Flange Arrangement

    On all modular sections for simple connection.

    Aura-FX Digital Gas Monitor

    • Real-time gas monitoring with live analysis and voice prompting
    • Monitor up to 11 gases at any one time

     

     

    CHAMBER EXTERIOR - REAR

    Communications Box

    Communications box for internal communications port via wall mounted 'J' box. External antenna is fitted to front of chamber.

    Air Conditioning Condenser

    Air conditioning is vital to combat the potentially fatal effects of heat stress, caused by the occupant’s metabolic activity, as well as any ambient heat .

    CAMS

    The MineARC Compressed Air Management System (CAMS) is a dedicated air management unit designed specifically for MineARC Refuge Chambers. Click for more information.

    Battery UPS

    36 hour emergency backup power supply, with further options available for up to 96 hours (POA).

     

    ENQUIRE BROCHURE

     


    Image
  • MineSAFE Permanent Shelter

     
     
    A permanent refuge chamber (as opposed to portable) can often prove to be a more efficient and cost effective solution for an underground mine. In particular, mines that;
             
    • Have a large number of personnel underground at any one time,
    • Have low excavation costs, and
    • Where the regular movement of personnel underground remains within certain areas.
             
    Permanent refuge chambers therefore often double as break, rest and lunch areas, capable of sheltering upwards of hundreds of personnel at any one time. – More information

    Image
    Image

     

     

    MineSAFE Permanent Refuge Rooms consist of a standard framework of recommended equipment, vital to safe operation of the shelter in an emergency. MineARC engineers work closely with each site to tailor a refuge model to best suit their requirements.

     

    CLICK FOR FURTHER INFORMATION BROCHURE

     

     

    STANDARD COMPONENTS

    Series IV Scrubber

    The MineARC Series IV Scrubber is the “Control Unit” of an expandable system that is capable of providing CO and CO2 scrubbing while also providing cooling/heating to large scale sealed environments.

    Air Conditioning

    All MineSAFE Permanent Shelters include quality reverse cycle split-system Mitsubishi Air Conditioners to both cool and dehumidify the refuge chamber.

    UPS Battery Backup

    The UPS is a fail safe system that can power the refuge chamber’s internal life support systems for a minimum of 36 hours should mains 'mine' power become cut-off.

    Compressed Oxygen Cylinder Racks

    If mine air supply fails, refuge chambers should be fitted with breathing grade O2 cylinders. Cylinders are to be provided by end user.

    Bulkhead Door

    Bulkhead doors are constructed from solid steel plate, with double-locking rotating handles, rubber seals, portal windows, and check valves to ensure a fully sealed environment.

     


     

    Air Conditioning UPS Battery Backup Compressed Oxygen Cylinder Rack Bulkhead Door Flushing Airlock Compressed Air Management System_Yellow Box
    Scrubbing    Air Con       UPS   Cylinders      Doors   Airlocks      CAMS

     

    CLICK FOR FURTHER INFORMATION BROCHURE

     


    Image
  • MineSAFE Training Chambers

    MineARC has developed a series of specially designed training chambers, designed to assist sites in the training and development of staff.
     
    The training chambers are available in three configurations – Standard Design with Series IV Scrubber, Standard Design with Series III Scrubber and Compact Design with ELVP Scrubber. They have been engineered to allow for convenient service, maintenance and operational training in an above-ground environment. – More information

    Image
    Image

     


     

    MineARC Training Chambers feature all of the major life-supporting features of a standard refuge chamber, including a scrubbing system, external mine air filter kit, battery bank and internal/external lighting and sirens. This allows sites to conduct comprehensive training in both the service and operation of all the vital componentry of a real-life MineARC Refuge Chamber.

     

    FEATURES

    • Aura-FX Fixed Gas Monitoring
    • Refuge chamber control and scrubbing system (Series IV, Series III or ELVP)
    • Chemical cartridge simulation props
    • External mine air filter kit
    • Oxygen candle (Standard Design models only)
    • Air conditioning and dehumidifying system
    • Four-battery bank to power control system
    • Internal lighting
    • External warning siren and strobe lights
    • Communications system
    • 4-person seating
    • Training manuals and video
    MineSAFE CD ELVP Training Chamber
    ENQUIRE BROCHURE

     

     


     

    MineSAFE SD SIV Training Chamber

    MINESAFE SD-SIV TRAINING CHAMBER

     

    The MineSAFE SD-SIV Training Chamber is engineered based on the MineARC's Standard Design refuge model and features the flagship Series IV controller and scrubbing system; the most advanced safe-refuge technology in the world. The system features improvements on the older Series III model, including:

    • i.V.A.N (Intelligent Voice Audio Navigation); an on-board navigation assistant that guides occupants through operational procedures
    • MARCISORB pre-packaged chemical cartridges
    • Improved data logging capabilities

    The Series IV Scrubber is also a feature of the ChemSAFE Standard Design chamber.

    The SD-SIV chamber also features the new Compressed Air Management System (CAMS), MineARC's latest innovation in providing external, breathable air to the refuge chamber.

     

    MineSAFE CD ELVP Training Chamber

    MINESAFE CD-ELVP TRAINING CHAMBER

     

    The MineSAFE CD-ELVP Training Chamber is engineered based on MineARC's Compact Design refuge model and features an ELVP (extra-low-voltage-portable) control system.

    The extra low voltage scrubber is also a feature of the TunnelSAFE range.

    The CD-ELVP chamber also features the new Compressed Air Management System (CAMS), MineARC's latest innovation in providing external, breathable air to the refuge chamber.

     

    MineSAFE SD SIII Training Chamber

    MINESAFE SD-SIII TRAINING CHAMBER

    The MineSAFE SD-SIII Training Chamber is engineered based on the Series III refuge chamber model, which was on the market between the years of 2009 and 2013. The chamber features the Series III electrical control system and free-pour scrubber chemicals, which are no longer offered by MineARC Systems but are still supported and in use by many sites across the globe.

    The SD-SIII chamber also features the original MineARC three-stage mine air filter pack; a method of providing external breathable air to the refuge chamber prior to the introduction of CAMS.

     

     

    ENQUIRE BROCHURE

     


    Image

Enewsletter Subscribe

Enewsletter Subscribe

Book an upgrade

For more information on MineARC upgrades, click here









Schedule Commissioning

For more information on MineARC commissioning, click here









Book an audit

For more information on MineARC audits, click here









Register for service school

For more information on MineARC Service School, click here








Order a remote service pack(s)

For more information on MineARC RSPs, click here








Close

Book a service

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Close

Book an upgrade

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Close

Schedule onsite training

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Close

Book an audit

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Close

Register for service school

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Close

Order a remote service pack(s)

minear_logo

Thank you for your request.

 

A MineARC Service Representative will be in contact
with you shortly to confirm your booking.

+ 61 8 9333 4966

service@minearc.com.au

Avant8